50 kVt quvvatga ega Perkins dizel generatori to'g'ridan-to'g'ri in'ektsiya yonish texnologiyasini qo'llagan holda Perkins 1103A/1104D seriyali turbo dvigatellari bilan jihozlangan. 4,4 litr sig‘imi bilan u 64 kVt quvvatga ega bo‘ladi va to‘liq yuklangan{6}}yoqilg‘i sarfi 214 g/kVt/soatgacha past bo‘ladi. Uning raqamli boshqaruv tizimi real vaqt rejimida 20 dan ortiq parametrlarni, jumladan kuchlanish, chastota va moy haroratini-kuza oladigan aqlli kontrollerni birlashtiradi. U masofadan ishga tushirish/to‘xtatish va nosozliklar haqida ogohlantirishni qo‘llab-quvvatlaydi, barqaror{12}}holat kuchlanishini tartibga solish tezligi ±0,5% dan kam yoki teng va chastota o‘zgarishi tezligi ±0,5% dan kam yoki teng bo‘lib, chiqish barqarorligini ta’minlaydi. Yuqori{16}}balandlik muhitlari uchun (balandlik 2000 metrdan katta yoki unga teng) yuqori{18}}balandlik versiyasi variant sifatida mavjud. Optimallashtirilgan qabul qilish tizimi va issiqlik tarqalish dizayni orqali quvvatning susayishi 10% ichida nazorat qilinadi.

Bir nechta konfiguratsiyalar, keng ilovalar
50 kVt quvvatga ega Perkins dizel generator to'plami qurilish maydonchalari, yo'llarni ta'mirlash va qurilish loyihalari, turar-joylardan foydalanish, supermarketlar, ochiq sayohat, cho'l lageri, akvakultura, qurilish guruhlari, tashqi qurilish, bog'ni ko'kalamzorlashtirish, ishlab chiqarish ustaxonalari, kemalar, neft konlari, reklama xonalari, avtoulovlarni saqlash tizimlari, uskunalarni saqlash tizimlari, UPS kabi turli stsenariylar va sohalarga xizmat ko'rsatadigan keng ko'lamli ilovalarni taklif etadi. RVs va chorvachilik.

Standart konfiguratsiyalar bilan jihozlangan 50 kVt quvvatga ega Perkins dizel generatorlari yetarli zaxiralarni saqlaydi.
Agar sizga boshqa konfiguratsiyalar kerak bo'lsa, iltimos, bizga to'g'ridan-to'g'ri xabar berishdan tortinmang.
Mavjud variantlar orasida jim tur, treyler turi va yomg'irga chidamli turi va boshqalar mavjud. Bundan tashqari, ATS avtomatik uzatish tizimini tanlash 50 kVt quvvatga ega Perkins dizel generator majmuasining umumiy texnik xususiyatlarini oshirishi mumkin.


50KW Perkins generatorlari to'plami parametrlari jadvali
|
Generator modeli |
Dizel generatori |
Dizel dvigatel |
Alternator |
Hajmi Lx WxH (mm) |
Og'irligi (KG) |
|||
|
Asosiy quvvat (KVt/KVA) |
Kutish rejimidagi quvvat (KVt/KVA) |
Model |
Quvvat (KVt) |
Model |
Quvvat (KWIKVA) |
|||
|
KNP8GF |
8/10 |
8.8/11 |
403A-11G1 |
8 |
PI044E |
8/10 |
1580x810x930 |
380 |
|
KNP10GF |
10/12.5 |
11/13.8 |
403A-15G1 |
12 |
PI044F |
10/12.5 |
1580x810x930 |
500 |
|
KNP16GF |
16/20 |
18/22.5 |
404A-22G1 |
18 |
PI144D |
16/20 |
1580x810x990 |
540 |
|
KNP24GF |
24/30 |
26/32.5 |
1103A-33G |
28 |
PI144G |
24/30 |
1580x810x1165 |
660 |
|
KNP28GF |
28/35 |
30.8/38.5 |
1103A-33G |
28 |
PI144H |
28/35 |
1595x810x1150 |
660 |
|
KNP32GF |
32/40 |
35.2/44 |
1103A-33TG1 |
41 |
PI144J |
32/40 |
1595x810x1150 |
730 |
|
KNP34GF |
34/42.5 |
37.4/46.8 |
1103A-33TG1 |
41 |
PI144K |
34/42.5 |
1595x810x1150 |
730 |
|
KNP40GF |
40/50 |
44/55 |
1103A-33TG1 |
41 |
UC1224D |
40/50 |
1580x810x1165 |
730 |
|
KNP48GF |
48/60 |
52/65 |
1103A-33TG2 |
54 |
UC1224E |
48/60 |
1580x810x1166 |
780 |
|
KNP58GF |
58/72.5 |
63.8/80 |
1104A-44TG1 |
58 |
UC1224F |
58/72.5 |
1760x810x1165 |
780 |
|
KNP68GF |
68/85 |
74.8/93.5 |
1104A-44TG2 |
72 |
UC1224G |
68/85 |
1760x810x1165 |
800 |
|
KNP80GF |
80/100 |
88/110 |
1104C-44TAG2 |
90 |
UC1274C |
80/100 |
3000x1000x1600 |
1030 |
|
KNP96GF |
96/120 |
105.6/132 |
1106A-70TG1 |
119 |
UC1274E |
96/120 |
2240x960x1315 |
1030 |
|
KNP112GF |
112/140 |
123.2/154 |
1106A-70TG1 |
119 |
UC1274E |
112/140 |
2190x810x1365 |
1250 |
|
KNP128GF |
128/160 |
140/176 |
1106A-70TAG2 |
130 |
UC1274F |
128/160 |
2240x960x1315 |
1300 |
|
KNP144GF |
144/180 |
158/198 |
1106A -70TAG3 |
157 |
UC1274G |
144/180 |
2345x810x1365 |
1300 |
|
KNP160GF |
160/200 |
176/220 |
1106A-70TAG4 |
174 |
UC1274H |
160/200 |
2240x960x1590 |
1300 |
|
KNP200GF |
200/250 |
220/275 |
1506A-E88TAG3 |
228 |
UCD274K |
200/250 |
2430x960x1590 |
2170 |
|
KNP240GF |
240/300 |
264/330 |
1506A-E88TAG5 |
273 |
HC144D |
240/300 |
3030x1120x1800 |
2500 |
|
KNP300GF |
300/375 |
330/412.5 |
2206C-E13TAG3 |
349 |
HC1444F |
300/375 |
3280x1130x1950 |
3300 |
|
KNP360GF |
360/450 |
400/500 |
2506C-E15TAG1 |
396 |
HC1544C |
360/450 |
3280x1130x1950 |
3800 |
|
KNP400GF |
400/500 |
440/550 |
2506C-E15TAG2 |
435 |
HC1544C |
400/500 |
3310x1180x1950 |
3940 |
|
KNP500GF |
500/625 |
550/690 |
2806A-E18TAG1A |
555 |
HC1544fS |
500/625 |
3380x1500x2100 |
4706 |
esda tuting
1. Yuqoridagi texnik parametrlar 50hz, nominal kuchlanish 400/230V, quvvat koeffitsienti 0,8, 3 fazali 4-sim, 60Hz generatorlari mijozlarning maxsus ehtiyojlariga muvofiq sozlanishi mumkin.
2. Alternatorlar Keneng, Stenford, Leroy- Somer, Marathon va boshqa mashhur brendlar kabi mijozlarning ehtiyojlariga qarab tanlanishi mumkin.
3. Texnik xususiyatlar ogohlantirishsiz o'zgarishi mumkin.
Nima uchun bizni tanlaysiz?
1. Perkins vakolatli hamkori sifatida biz original sifat kafolatini taqdim etamiz. 50 kVt quvvatga ega generator majmualarining barcha asosiy komponentlari (masalan, dvigatellar) asl ishlab chiqaruvchi tomonidan yetkazib beriladi.
2. Standart konfiguratsiyaga ega 50 kVt quvvatga ega Perkins dizel generatorlari uchun biz tezkor yetkazib berishni ta'minlash uchun yetarli zaxirani saqlab turamiz. Moslashtirish talablari uchun (masalan, jim tur, treyler turi, ATS va boshqalar) etuk ta’minot zanjiri tizimimizga tayanib, biz moslashtirilgan konfiguratsiya ehtiyojlariga samarali javob bera olamiz va yetkazib berish vaqtini qisqartiramiz.
3. Qattiq zavod tekshiruvlari (jumladan, yuk sinovlari, ishlashni kalibrlash va h.k.) orqali biz 50 kVt quvvatga ega generator to'plamlarining yetkazib berish vaqtida barqaror ishlashini ta'minlaymiz.



50 kVt quvvatga ega Perkins dizel generatorlari to'plami haqida tez-tez so'raladigan savollar
Savol: 50 kVt quvvatga ega Perkins dizel generatori qaysi dizeldan foydalanishi kerak? Harorat o'zgarishi uchun modelni almashtirish kerakmi?
Javob: Muntazam ravishda 0 # dizeldan foydalaning; yonilg'ining mum bo'lishini oldini olish uchun -10 darajadan pastda -10 # dizelga o'ting.
Savol: 50 kVt quvvatga ega Perkins dizel generatorini nam yoki qirg‘oq bo‘yida ishlatish bo‘yicha ehtiyot choralari bormi?
Javob: Elektr qismlarini muntazam tozalang, namlik o'tkazmaydigan{0}}qopqoqlarni qo'shing va terminallar muhrlanganligini tekshiring.
Savol: 50 kVt quvvatga ega Perkins dizel generatoriga texnik xizmat ko'rsatish sikli har xil yuk stavkalari bilan o'zgaradimi?
Javob: Asosiy parvarishlash davri 500 soat; uzoq{2}}muddatli to'liq-yuklash uchun 400 soatgacha qisqartiriladi.
