Yuchai 1800kVt dizel generator to'plamining mahsulot xususiyatlari YC16VC330-D31
To'rt{0}}klapan, to'rt{1}}bosqichli turbo zaryadlash, yuqori-samarador sovutish va Yuchai yonish kamerasi texnologiyasini qo'llagan holda, u kam yoqilg'i sarfi, kam emissiya, ajoyib vaqtinchalik javob va tez, kuchli yuklanishga erishadi.
Yog 'kirish bosimini oshirish, turli ish sharoitida barqaror yoqilg'i ta'minotini ta'minlash, optimal tejamkorlik uchun yonish samaradorligini oshirish uchun qo'shimcha yonilg'i uzatish pompasi o'rnatilgan.
Korpus mustahkamlangan qovurg‘a panjarali tuzilmasi va to‘rt-boltli asosiy podshipnik dizayniga ega bo‘lgan-bardoshli materiallardan foydalanadi, ular yuqori qattiqlik, past tebranish va past shovqinni ta’minlaydi.
Krank mili yuqori sifatli qotishma-po'latdan yasalgan; uning millari diametrlari va filetolari so'ndirilgan va qattiqlashtirilgan issiqlik bilan ishlov berishdan o'tadi, bu aşınmaya bardoshli va uzoq xizmat muddatini ta'minlaydi.
Jahon darajasidagi uskunalar va texnologiya-bilan ishlab chiqarilgan u barqaror va ishonchli sifatni taklif etadi. Bir{2}}tsilindrli-bir-boshli konstruksiyaga ega boʻlib, yon panellari bilan taʼmirlashni osonlashtiradi. Ushbu konfiguratsiya generator to'plamlari uchun G3-darajali ishlash talablariga to'liq mos keladi.

Bir nechta konfiguratsiyalar, keng ilovalar
1800 kVt quvvatga ega Yuchai dizel generatorlari uchun ixtiyoriy konfiguratsiyalar:
1. Avtomatik ishga tushirishni boshqarish tizimi
2. Avtomatik yuk o'tkazgich (ATS) paneli
3. Yomg'irga chidamli generatorlar to'plami (shkaf korpusi)
4. Jim generator to'plami (shkaf korpusi)
5. Mobil treyler-oʻrnatilgan elektr stansiyasi (shkaf tirkamasi)
6. Ovozsiz mobil elektr stantsiyasi (kabinet tirkamasi)
7. Yog ', dizel, suv ko'ylagi va-kondensatsiyaga qarshi isitgichlar
8. Ajratilgan{1}}kunlik yoqilg'i baki, o'rnatilgan asosiy yonilg'i baki



1800KW Yuchai generator to'plami parametrlar jadvali
|
Generator modeli |
Dizel generatori |
Dizel dvigatel |
Alternator |
Hajmi Lx WxH (mm) |
Og'irligi (KG) |
|||
|
Asosiy quvvat (KVt/KVA) |
Kutish rejimidagi quvvat (KVt/KVA) |
Model |
Quvvat (KVt) |
Model |
Quvvat (KWIKVA) |
|||
|
KNY20GF |
20/25 |
22/27.5 |
YC4V35-D20 |
23/25 |
KN-20 |
20/25 |
1800x750x1200 |
920 |
|
KNY30GF |
30/37.5 |
33/41.25 |
YC4V45-D20 |
30/33 |
KN-30 |
30/37.5 |
1800x750x1200 |
950 |
|
KNY35GF |
35/43.75 |
40/50 |
YC4V55Z-D20 |
38/42 |
KN-35 |
35/43.75 |
1800x700x1200 |
980 |
|
KNY40GF |
40/50 |
44/55 |
YC4D60-D25 |
40/44 |
KN-40 |
40/50 |
1800x700x1200 |
1000 |
|
KNY50GF |
50/62.5 |
55/68.75 |
YC4D90Z-D21 |
60/66 |
KN-50 |
50/62.5 |
2250x800x1300 |
1250 |
|
KNY60GF |
60/75 |
66/82.5 |
YC4A100Z-D25 |
70/77 |
KN-60 |
60/75 |
2300x800x1300 |
1500 |
|
KNY75GF |
80/100 |
88/110 |
YC4A140L-D25 |
100/110 |
KN-80 |
80/100 |
2300x830x1300 |
1600 |
|
KNY100GF |
100/125 |
110/137.5 |
YC4A180L-D20 |
120/132 |
KN-100 |
100/125 |
2400x970x1500 |
2100 |
|
KNY120GF |
120/150 |
132/165 |
YC6B205L-D20 |
138/152 |
KN-120 |
120/150 |
3100x1050x1750 |
2750 |
|
KNY150GF |
150/187.5 |
165/206.25 |
YC6A245L-D21 |
165/181 |
KN-150 |
150/187.5 |
3200x1150x1750 |
3000 |
|
KNY200GF |
200/250 |
220/275 |
YC6MK350L-D20Y |
235/258 |
KN-200 |
200/250 |
3200x1200x1750 |
3100 |
|
KNY250GF |
250/312.5 |
275/343.75 |
C6MK420L-D20 |
281/309 |
KN-250 |
250/312.5 |
3400x1500x1970 |
3900 |
|
KNY300GF |
300/375 |
330/412.5 |
YC6MJ500L-D21 |
334/367 |
KN-300 |
300/375 |
3500x1500x1970 |
4000 |
|
KNY350GF |
350/437.5 |
385/481.25 |
YC6K600-D30 |
401/441 |
KN-350 |
350/437.5 |
3500x1500x1970 |
4500 |
|
KNY400GF |
400/500 |
440/550 |
YC6K660-D30 |
441/490 |
KN-400 |
400/500 |
4500x1800x2500 |
7500 |
|
KNY500GF |
500/625 |
550/687.5 |
YC6TD840-D30 |
561/616 |
KN-500 |
500/625 |
5000x2000x2500 |
9800 |
|
KNY600GF |
600/750 |
660/825 |
YC6TD1000-D30 |
668/735 |
KN-600 |
600.75 |
5300x2080x2500 |
10000 |
|
KNY800GF |
800/1000 |
880/1100 |
YC6TH1320-D31 |
880/968 |
KN-800 |
800/1000 |
5600x2280x2600 |
12000 |
|
KNY1000GF |
1000/1250 |
1100/1375 |
YC6C1660-D31 |
1110/1221 |
KN-1000 |
1000/1250 |
5600x2280x2600 |
12000 |
|
KNY1200GF |
1200/1500 |
1320/1650 |
YC12VC2070-D31 |
1380/1520 |
KN-1300 |
1200/1500 |
5600x2280x2600 |
13000 |
|
KNY1500GF |
1500/1875 |
1650/2062.5 |
YC12VC2700-D31 |
1805/1985 |
KN-1600 |
1500/1875 |
5600x2280x2600 |
14000 |
|
KNY1800GF |
1800/2250 |
1980/2475 |
YC16VC330C-D31 |
2205/2426 |
KN-1800 |
1800/2250 |
5600x2280x2600 |
14000 |
|
KNY2000GF |
2000/2500 |
2200/2750 |
YC16VC4C0C-D31 |
2673/2940 |
KN-2000 |
2000/2500 |
5600x2280x2600 |
14000 |
esda tuting
1. Yuqoridagi texnik parametrlar 50hz, nominal kuchlanish 400/230V, quvvat koeffitsienti 0,8, 3 fazali 4-sim, 60Hz generatorlari mijozlarning maxsus ehtiyojlariga muvofiq sozlanishi mumkin.
2. Alternatorlar Keneng, Stenford, Leroy- Somer, Marathon va boshqa mashhur brendlar kabi mijozlarning ehtiyojlariga qarab tanlanishi mumkin.
3. Texnik xususiyatlar ogohlantirishsiz o'zgarishi mumkin.
Nima uchun bizni tanlaysiz?
Biz 20 kVt dan 2000 kVt gacha quvvatga ega Yuchai dizel generatorlarini taklif qilamiz. Mijozlar o'zlarining korxonalarining haqiqiy energiya iste'moli ehtiyojlari va byudjet cheklovlari asosida tegishli Yuchai modelini tanlashlari mumkin. Qo'shimcha Yuchai generator to'plami modellari haqida qo'shimcha ma'lumot olish uchun, iltimos, kengroq variantlar bo'yicha batafsil tavsiyalar uchun mijozlarga xizmat ko'rsatish bo'limiga murojaat qiling.



1800 kVt quvvatga ega Yuchai dizel generatorlari uchun texnik xizmat ko'rsatishning asosiy nuqtalari
1. Kundalik tekshiruvlarni o'tkazing, asosan yoqilg'i idishidagi yoqilg'i darajasini etarli miqdorda yoqilg'i bilan ta'minlash uchun tekshiring; kerak bo'lganda o'z vaqtida yonilg'i quyish.
2. Dizel generator majmuasining tashqi yuzasini toza tuting.
3. Ishlash vaqti taxminan 500 soatga yetganda, uchta filtrni almashtiring: yog 'filtri, dizel filtri va havo filtri.
4. Mahkamlagich komponentlarini tekshiring: Dizel dvigatelining ishlashi vaqtida tebranishlar, notekis yuklar va boshqalar ta'siridan murvat va yong'oqlar bo'shashishga moyil. Dvigatel korpusiga zarar etkazishi mumkin bo'lgan bo'shashmasdan kelib chiqadigan baxtsiz hodisalarning oldini olish uchun sozlash murvatlarini turli pozitsiyalarda tekshiring.
5. Hech qachon generatorning nam bo'lishiga yo'l qo'ymang. Metall qoldiqlari, namlik yoki boshqa zararli gazlarning generatorning ichki qismiga kirishiga yo'l qo'ymang.