280 kVt quvvatga ega Perkins generatori asosiy dizel yonish tamoyillari asosida ishlaydi. Tsilindrga toza havo kiradi va yuqori bosim ostida nozik püskürtülmüş dizel yoqilg'isi bilan aralashadi. Piston bu aralashmani siqib chiqarganda, harorat yonish sodir bo'lgunga qadar tez ko'tariladi va bu kuchli kengayish hosil qiladi, bu esa quvvat zarbasi deb nomlanuvchi pistonni pastga yo'naltiradi. Bu chiziqli harakat birlashtiruvchi novdalar va krank mili orqali aylanish energiyasiga aylanadi.
To'g'ridan-to'g'ri krank miliga o'rnatilgan, cho'tkasi bo'lmagan AC alternatorining rotori stator majmuasi ichida aylanadi. Elektromagnit induktsiya - orqali magnit maydon orqali harakatlanuvchi o'tkazgich elektr tokini hosil qiladi - bu mexanik aylanish foydalanish mumkin bo'lgan elektr energiyasiga aylanadi. Bir nechta tsilindrlarning ketma-ket yonishi barqaror elektr ishlab chiqarish uchun zarur bo'lgan silliq, uzluksiz quvvat chiqishini ta'minlaydi.

280 kVt Perkins dizel generatorlari to'plamining ishlashi
1. GB2820 va ISO8528/3 standartlariga mos keladi.Shuningdek, u pochta va telekommunikatsiya tizimlariga bag'ishlangan dizel generatorlari uchun YD/T502 texnik talablariga javob beradi.
Nominal kuchlanish: 400/230V
O'tkazgich konfiguratsiyasi: 3 fazali 4 simli
Chastotasi: 50Hz
Nominal quvvat koeffitsienti: 0,8 (kechikish)
Radio shovqinlarini bostirish: VDE0875-N sinfi va GB2820 qoidalariga mos keladi.
2. Perkins generator majmuasi uchun standartlar:
GB/T2819, ISO8528 va IEC34 kabi xalqaro standartlarning spetsifikatsiyalariga mos keladi;
Jeneratör to'plamining nominal chiqish quvvati tegishli standartlarga mos keladi;
1000 m dan yuqori bo'lmagan balandlik;
Atrof-muhit harorati: 0 darajadan 40 darajagacha;
Havoning nisbiy namligi: 60%.
3. Perkins generator majmuasining alternatori:
Qo'zg'alish usuli: cho'tkasiz o'z{0}}qo'zg'alish
Izolyatsiya sinfi: H klassi
Himoya klassi: IP21 ~ IP23
Voltajni tartibga solish: Avtomatik tartibga solish
4. Perkins generator majmuasining boshqaruv shkafi:Har xil turdagi boshqaruv kabinetlari mavjud, jumladan qo'lda, avtomatik, masofaviy monitoring va to'liq avtomatik aqlli. Asosiy konfiguratsiyalarga voltmetr, ampermetr, suv harorati o'lchagich, yog 'bosimi o'lchagich, boshqaruvchi, favqulodda to'xtatish tugmasi, oldindan isitish tugmasi, batareya voltmetri, taymer va fazani tanlash tugmasi kiradi.



280KW Perkins generatorlari to'plami parametrlari jadvali
|
Generator modeli |
Dizel generatori |
Dizel dvigatel |
Alternator |
Hajmi Lx WxH (mm) |
Og'irligi (KG) |
|||
|
Asosiy quvvat (KVt/KVA) |
Kutish rejimidagi quvvat (KVt/KVA) |
Model |
Quvvat (KVt) |
Model |
Quvvat (KWIKVA) |
|||
|
KNP8GF |
8/10 |
8.8/11 |
403A-11G1 |
8 |
PI044E |
8/10 |
1580x810x930 |
380 |
|
KNP10GF |
10/12.5 |
11/13.8 |
403A-15G1 |
12 |
PI044F |
10/12.5 |
1580x810x930 |
500 |
|
KNP16GF |
16/20 |
18/22.5 |
404A-22G1 |
18 |
PI144D |
16/20 |
1580x810x990 |
540 |
|
KNP24GF |
24/30 |
26/32.5 |
1103A-33G |
28 |
PI144G |
24/30 |
1580x810x1165 |
660 |
|
KNP28GF |
28/35 |
30.8/38.5 |
1103A-33G |
28 |
PI144H |
28/35 |
1595x810x1150 |
660 |
|
KNP32GF |
32/40 |
35.2/44 |
1103A-33TG1 |
41 |
PI144J |
32/40 |
1595x810x1150 |
730 |
|
KNP34GF |
34/42.5 |
37.4/46.8 |
1103A-33TG1 |
41 |
PI144K |
34/42.5 |
1595x810x1150 |
730 |
|
KNP40GF |
40/50 |
44/55 |
1103A-33TG1 |
41 |
UC1224D |
40/50 |
1580x810x1165 |
730 |
|
KNP48GF |
48/60 |
52/65 |
1103A-33TG2 |
54 |
UC1224E |
48/60 |
1580x810x1166 |
780 |
|
KNP58GF |
58/72.5 |
63.8/80 |
1104A-44TG1 |
58 |
UC1224F |
58/72.5 |
1760x810x1165 |
780 |
|
KNP68GF |
68/85 |
74.8/93.5 |
1104A-44TG2 |
72 |
UC1224G |
68/85 |
1760x810x1165 |
800 |
|
KNP80GF |
80/100 |
88/110 |
1104C-44TAG2 |
90 |
UC1274C |
80/100 |
3000x1000x1600 |
1030 |
|
KNP96GF |
96/120 |
105.6/132 |
1106A-70TG1 |
119 |
UC1274E |
96/120 |
2240x960x1315 |
1030 |
|
KNP112GF |
112/140 |
123.2/154 |
1106A-70TG1 |
119 |
UC1274E |
112/140 |
2190x810x1365 |
1250 |
|
KNP128GF |
128/160 |
140/176 |
1106A-70TAG2 |
130 |
UC1274F |
128/160 |
2240x960x1315 |
1300 |
|
KNP144GF |
144/180 |
158/198 |
1106A -70TAG3 |
157 |
UC1274G |
144/180 |
2345x810x1365 |
1300 |
|
KNP160GF |
160/200 |
176/220 |
1106A-70TAG4 |
174 |
UC1274H |
160/200 |
2240x960x1590 |
1300 |
|
KNP200GF |
200/250 |
220/275 |
1506A-E88TAG3 |
228 |
UCD274K |
200/250 |
2430x960x1590 |
2170 |
|
KNP240GF |
240/300 |
264/330 |
1506A-E88TAG5 |
273 |
HC144D |
240/300 |
3030x1120x1800 |
2500 |
|
KNP300GF |
300/375 |
330/412.5 |
2206C-E13TAG3 |
349 |
HC1444F |
300/375 |
3280x1130x1950 |
3300 |
|
KNP360GF |
360/450 |
400/500 |
2506C-E15TAG1 |
396 |
HC1544C |
360/450 |
3280x1130x1950 |
3800 |
|
KNP400GF |
400/500 |
440/550 |
2506C-E15TAG2 |
435 |
HC1544C |
400/500 |
3310x1180x1950 |
3940 |
|
KNP500GF |
500/625 |
550/690 |
2806A-E18TAG1A |
555 |
HC1544fS |
500/625 |
3380x1500x2100 |
4706 |
esda tuting
1. Yuqoridagi texnik parametrlar 50hz, nominal kuchlanish 400/230V, quvvat koeffitsienti 0,8, 3 fazali 4-sim, 60Hz generatorlari mijozlarning maxsus ehtiyojlariga muvofiq sozlanishi mumkin.
2. Alternatorlar Keneng, Stenford, Leroy- Somer, Marathon va boshqa mashhur brendlar kabi mijozlarning ehtiyojlariga qarab tanlanishi mumkin.
3. Texnik xususiyatlar ogohlantirishsiz o'zgarishi mumkin.
Nima uchun bizni tanlaysiz?
280 kVt quvvatga ega Perkins dizel generator majmuasi, shuningdek, foydalanuvchilarning turli ehtiyojlarini qondirish uchun qo'lda boshqarish, avtomatik boshqarish, masofadan boshqarish va boshqalar kabi turli xil boshqaruv echimlarini taklif etadi. Perkins generatorlari yuqori moslashuvchanlik va moslashtirish bilan faxrlanadi, ular turli sohalarda dastur talablariga javob berish uchun foydalanuvchilarning maxsus ehtiyojlari va talablariga muvofiq sozlanishi va ishlab chiqilishi mumkin.



280 kVt quvvatga ega Perkins dizel generatorlari to'plami haqida tez-tez so'raladigan savollar
Savol: Balandlikdagi hududlarda foydalanish uchun-qanday tuzatishlar kerak?
Javob: Balandlik 1000 m dan oshganda quvvatni kamaytirish va havo olish tizimining silliqligini tekshirish tavsiya etiladi.
Savol: Boshqaruv kabinetining qo'lda va avtomatik rejimlari o'rtasida qanday o'tish mumkin?
Javob: Avval jihozni to'xtating, rejimni tanlash tugmachasini o'zgartiring va mos keladigan indikator yoniqligini tasdiqlang.
Savol: H sinfidagi izolyatsion generatorlarga kundalik texnik xizmat ko'rsatishning asosiy nuqtalari qanday?
Javob: Muntazam ravishda o'rashdan changni tozalang va izolyatsiya qarshilik qiymati belgilangan standartdan pastga tushmasligiga ishonch hosil qiling.